Littelfuse Sxx70x Series Manual do Utilizador Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 8
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 3
334
Revised: 09/23/13
©2013 Littelfuse, Inc
Specifications are subject to change without notice.
Teccor
®
brand Thyristors
65 / 70 Amp Standard SCRs
Sxx65x & Sxx70x Series
Figure 7: Maximum Allowable Case Temperature vs. Average On-State Current
70
75
80
85
90
95
100
105
110
11 5
120
125
130
0 5 10 15 20 25 30 35 40 4550
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 180°
Sxx65K
Sxx65J
Maximum Allowable Case Temperature
(T
C
) - °C
Average On-State Current [I
T(AVE)
] - Amps
Sxx70W
The "K" package rating with its narrow leads is
intended for high surge condition use only and not
recommended for >32A (AV) continuous current use
since lead temperature depending on lead length can
exceed PCB solder melting temperature. "J" or "W"
packages are recommended for >32A (AV) continu-
ous current requirements.
10
100
1000
1 10 100 1000
Sxx65K
Sxx65J
Sxx70W
Surge Current Duration -- Full Cycles
Peak Surge (Non-repetitive)
On-state Current (I
TSM
) – Amps
Figure 10: Surge Peak On-State Current vs. Number of Cycles
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [I
T(RMS)
]: Maximum Rated
Value at Specified Case Temperature
Notes:
1. Gate control may be lost during and immediately
following surge current interval.
2. Overload may not be repeated until junction
temperature has returned to steady-state
rated value.
Figure 8: Peak Capacitor Discharge Current Figure 9: Peak Capacitor Discharge Current Derating
100
1000
10000
0.5 1.
0 10.0 50.0
Peak Discharge Current (I
TM
) - Amps
Pulse Current Duration (t
w
) - ms
I
TRM
t
W
0.0
0.2
0.4
0.6
0.8
1.0
1.2
0255075 100 12
5 150
Normalized Peak Current
Case Temperature (T
C
) - °C
Note: xx = Voltage
Vista de página 3
1 2 3 4 5 6 7 8

Comentários a estes Manuais

Sem comentários