1
Revised: 01/06/14
Specifications are subject to change without notice.
©2014 Littelfuse, Inc
Teccor
®
brand Thyristors
High Energy Unidirectional SIDACs
K2xx0GHURP Series
K2xx0yHU Series
Description
The new K2xx0yHU is a higher energy SIDAC switch for gas
ignition applications requiring higher current pulse current
especially at low repetition rate. It is offered in a DO-15
leaded package and DO-214AA surface mount package.
Voltage activation of this solid state switch is accomplished
with peak voltage level of 190 to 260Volts. The SIDAC is
a silicon bilateral voltage triggered Thyristor switch that
switches on through a negative resistance region to a low
on-state voltage. Conduction will continue until current is
interrupted or lowered below minimum holding current of
the device.
Features
Electrical Specifications (T
J
= 25°C, unless otherwise specified)
Symbol Parameters Test Conditions Min Max Unit
V
BO
Breakover/Trigger Voltage
K2000yHU 190 210
V
K2200yHU 210 230
K2400yHU 230 250
K2500yHU 240 260
V
DRM
Repetitive Peak Off-state Voltage
K2000yHU 180
V
K2200yHU 190
K2400yHU 210
K2500yHU 220
I
T(RMS)
On-state RMS Current
50/60Hz, T
J
< 125°C
1 A
V
TM
Peak On-state Voltage
I
T
= 1A
1. 5 V
I
H
Dynamic Holding Current
R
L
= 100Ω
50/60Hz Sine Wave
60 mA
R
S
(V
BO
– V
S
)
Switching Resistance, R
S
=
________
(I
S
– I
BO
)
50/60Hz Sine Wave 10 0
Ω
I
BO
Breakover Current 50/60Hz Sine Wave 500 μA
I
TRM
Peak Repetitive Pulse Current
(refer to figure 4)
t
p
= 10μs
60Hz 120
A
5Hz 280
di/dt Critical Rate of Rise of On-State Current 220 A/μs
dv/dt Critical Rate of Rise of Off-State Voltage 1500 V/μs
T
S
Storage Temperature Range -40 150 °C
T
J
Junction Temperature Range -40 125 °C
R
θJL
Thermal Resistance, Junction to Lead
DO-15 18
°C/W
DO-214AA 30
R
θJA
Thermal Resistance, Junction to Ambient DO-15 75 °C/W
Schematic Symbol
Applications
Suitable for high voltage power supplies, natural gas
igniters, and Xenon flash ignition.
• AC circuit oriented
• Triggering Voltage of 190
to 260V
• 280A Pulse current
capability
• RoHS compliant
• Unidirectional
Note: xxx - voltage, y = package
K
A
Comentários a estes Manuais