© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 12/19/13
Surface Mount Fuses
Surge Resistant > 461 Series TeleLink
®
Fuse
Electrical Specifications by Item
Ampere
Rating
(A)
Amp Code
Max
Voltage
Rating
(V)
Interrupting
Rating
Nominal Cold
Resistance (Ohms)
Nominal Melting
I
2
t (A
2
sec)
Agency Approvals
0.500 .500 600
60 A @600 VAC
100 A @80 VDC
0.560 0.840
1
x x
1.25 1.25 600 0.110 16.5
1
x x
2.00 002. 600 0.050 17. 5
1
x x
1
I
2
t is calculated at 10 msecs. or less. I
2
t at 10 times rated current has a typical value of: 24 A
2
sec (2.0A), 22 A
2
sec (1.25A), 1.3 A
2
sec (0.5A).
• Typicalinductance<40nHupto500MHz.
• Resistancechanges0.5%forevery°C.
• Resistanceismeasuredat10%ratedcurrent.
GR 1089 Inter-building requirements
GR 1089 1st level lighting surge inter-building
(Equipment under test can not be damaged and must
continue to operate properly)
Surge
Minimum
Peak
Voltage
(V)
Minimum
Peak
Current
(A)
Max.
Rise/Min.
Decay
(µs)
Repetitions
Each
Polarity
Fuse
Choices
1 600 100 10/1000 25 1.25, 2.0
2 1000 100 10/360 25 1.25, 2.0
3 1000 100 10/1000 25 1.25, 2.0
4 2500 500 2/10 10 1.25, 2.0
5 1000 25 10/360 5 0.5, 1.25, 2.0
GR 1089 2nd level lightning surge telecom port
(Equipment under test shall not become a fire or
electrical safety hazard)
Surge
Minimum
Peak
Voltage
(V)
Minimum
Peak
Current (A)
Max.
Rise/Min.
Decay
(µs)
Repe-
titions
Each
Polarity
Fuse
Choices
1 5000 500 2/10 1 0.5, 1.25, 2.0
Alter-
native
5000 500/8=625 8/10 1 0.5, 1.25, 2.0
If sufficient series resistance is used, then the 0.5 fuse may be used in test conditions 1-4.
The 0.5 fuse will open during these test conditions. The 1.25 & 2.0 will not open thus
providing operational compliance.
Average Time Current Curves
10001001010.1
0.001
0.01
0.1
1
10
100
CURRENT IN AMPERES
TIME IN SECONDS
1.25A
2A
.500A
Temperature Rerating Curve
Note:
1. Rerating depicted in this curve is in addition to the standard rerating of 25% for
continuous operation.
Comentários a estes Manuais